  keysight technologies serial bus options for infiniivision x-series oscilloscopes data sheet
introduction serial buses are pervasive in todays digital designs and are used for a variety of purposes including on- board chip-to-chip communication, cpu to peripheral control, as well as for remote sensor data transfer and control. without intelligent oscilloscope serial bus triggering and protocol decode, it can be difficult to debug these buses and correlate data transfers with other mixed signal interactions in your system. keysight technologies, inc. infiniivision x-series oscilloscopes (dsos) and mixed-signal oscilloscopes (msos) offer optional integrated serial bus triggering and hardware-based protocol decoding solutions that give you the tools you need to accelerate debug of your designs that include serial bus communication. supported protocols and features C i 2 c C spi C rs232/uart C can C can fd (except 2000 x-series) C can-dbc symbolic decode and trigger (except 2000 x-series) C lin C lin-ldf symbolic decode and trigger (except 2000 x-series) C sent (3000t, 4000 and 6000 x-series only) C cxpi (3000t and 4000 x-series only) C flexray (except 2000 x-series) C usb 2.0 low- and full-speed (4000 and 6000 x-series) C usb 2.0 hi-speed (4000 and 6000 x-series only) C usb 2.0 signal quality (4000 and 6000 x-series only) C i 2 s (except 2000 x-series) C mil-std 1553 (except 2000 x-series) C arinc 429 (except 2000 x-series) C hardware-based decoding C multi-bus analysis (except 2000 x-series) C automatic search and navigation C compatibility with segmented memory acquisition C eye-diagram mask files available for can, flexray, mil-std 1553, and arinc 429 (requires dsox2mask/dsox3mask/dsox4mask/dsox6mask mask test option) C flexray physical layer conformance test software (except 2000 x-series)
03 | keysight | serial bus options for infiniivision x-series oscilloscopes - data sheet figure 1. hardware-based decoding quickly reveals serial communication errors. figure 3. automatic search & navigation quickly finds user- specified serial bus frames/bytes of interest. figure 2. symbolically decoding the can bus. hardware-based decoding keysights infiniivision series oscilloscopes are the industrys only keysights infiniivision series oscilloscopes are the industrys only scopes to use hardware-based decoding. most other vendors scopes with serial bus triggering and protocol decode, use software post-processing techniques to decode serial packets/ frames. with these software techniques, waveform- and decode- update rates tend to be slow (sometimes seconds per update.) thats especially true when using deep memory, which is often required to capture multiple packetized serial bus signals. and when analyzing multiple serial buses simultaneously, software techniques can make decode update rates even slower. faster decoding with hardware-based technology enhances scope usability, and more importantly, the probability of capturing infrequent serial communication errors. figure 1 shows an example of a keysight infiniivision x-series scope capturing a random and infrequent can error frame. the upper half of the scopes display shows the decoded data in a lister format, along with a time-correlated decode trace shown below the waveform. symbolic trigger and decode with the dsoxt3auto, dsox4auto or dsox6auto option licensed on a 3000t, 4000 or 6000 x-series oscilloscope, you can import a .dbc file that defines your multi-node can network. the oscilloscope can then trigger on and decode the can bus symbolically as shown in figure 2. lin symbolic trigger and decode is also supported on the 3000t, 4000, and 6000 x-series oscilloscopes by importing an industry-standard .ldf file. automatic search and navigation after capturing a long record of serial bus communication using the infiniivision scopes megazoom deep memory, you can easily perform a search operation based on specific criteria that you enter. then, you can quickly navigate to bytes/frames of serial data that satisfy the entered search criteria. figure 3 shows an example of searching on captured i2c data to find all occurrences of read or write operations with no ack. in this case, the scope found five occurrences of data transfers with no ack, and marked each occurrence with a white triangle to show where in time they happened relative to the captured waveform. navigating and zooming-in on each marked byte/frame is quick and easy using the scopes front panel navigation keys. search and navigation not available for dsoxt3cxpi/DSOX4CXPI.
04 | keysight | serial bus options for infiniivision x-series oscilloscopes - data sheet figure 4. an interleaved lister makes it easier to time-correlate activity between two decoded serial buses. figure 5. segmented memory acquisition selectively captures more packets/bytes of serial bus activity. multi-bus analysis many of todays designs include multiple serial buses. sometimes it may be necessary to correlate data from one serial bus to another. keysights infiniivision 3000, 4000 and 6000 x-series oscilloscopes can decode two serial buses simultaneously using hardware-based decoding. plus they are the only scopes on the market that can also display the captured data in a time- interleaved lister display, as shown in figure 4. in this particular example, the scope has simultaneously decoded and interleaved a can and lin bus in an automotive system. packetsthe segmented memory option for keysights infiniivision x-series oscilloscopes (standard in 3000t, 4000 and 6000 x-series) can optimize your scopes memory, letting you capture more packets/frames of serial bus activity. segmented memory acquisition optimizes the number of packetized serial communication frames that can be captured consecutively. segmented memory does this by capturing just the selective frames/bytes of interest while ignoring (not digitizing) idle time and other unimportant frames/bytes. figure 5 shows an example of the oscilloscope capturing 500 consecutive hi-speed usb split packets for a total acquisition time of approximately 200 ms. capturing this much data using conventional oscilloscope acquisition memory would require 1g bytes of memory. keysights infiniivision x-series oscilloscopes are the only scopes on the market today that can acquire segments on up to four analog channels of acquisition, and time-correlated segments on digital channels (using an mso model), along with automatic hardware-based serial bus decoding for each segment. in addition, you can use the scopes search and navigation capability after a segmented memory acquisition has been performed. using segmented memory to capture multiple serial bus
05 | keysight | serial bus options for infiniivision x-series oscilloscopes - data sheet the following can mask files are available: C 125 kbps C 400 meters C 250 kbps C 200 meters C 500 kbps C 10 meters C 500 kbps C 80 meters C 800 kbps C 40 meters C 1000 kbps C 25 meters mask files for can fd are also available (3000, 4000, and 6000 x-series only). can fd eye-diagrams are based on the first 10 bits of the fd phase from all frames. figure 7. flexray tp4 eye-diagram mask test. figure 8. mil-std 1553 bc to rt xfrm-coupled input mask test reveals a shifted bit that violates the pass/fail mask. figure 6. can 500 kbps mask test on 10 meter system. serial bus eye-diagram and pulse mask testing with the addition of the dsox2mask, dsox3mask, dsox4mask or dsox6mask mask test option, which can perform over 200,000 pass/fail tests (50,000 on 2000 x-series) per second, you can perform eye-diagram and pulse mask testing on can signals on all infiniivision x-series oscilloscopes. eye-diagram mask testing on flexray, mil-std 1553, and arinc 429 signals can be performed using an infiniivision 3000, 4000 or 6000 x-series oscilloscope. eye-diagram measurements provide a comprehensive signal quality test of the integrity of your transmitted and received signals. keysight provides various mask files that you can download at no charge. the mask files are based on published industry mask standards and/or derived from physical layer/electrical specifications. the following mil-std 1553 mask test files are available: C system xfmr-coupled input C system direct-coupled input C bc xfmr-coupled input C bc direct-coupled input C rt xfmr-coupled input C rt direct-coupled input the following flexray mask test files are available: C tp1 standard voltage (10 mbps only) C tp1 increased voltage (10 mbps only) C tp11 standard voltage (10 mbps only) C tp11 increased voltage (10 mbps only) C tp4 10 mbps C tp4 5 mbps C tp4 2.5 mbps
06 | keysight | serial bus options for infiniivision x-series oscilloscopes - data sheet the following arinc 429 mask/pulse test files are available: C 100 kbps eye test C 100 kbps 1s pulse test C 100 kbps 0s pulse test C 100 kbps null level test C 12.5 kbps eye test C 12.5 kbps 1s pulse test C 12.5 kbps 0s pulse test C 12.5 kbps null level test for additional information about eye-diagram mask testing on can, flexray, mil-std 1553, and arinc 429 signals, refer to the application notes listed at the end of this document. automated physical layer conformance testing to perform usb 2.0 signal quality testing based on usb-if compliance standards, keysight offers the dsox4usbsq or dsox6usbsq options on infiniivision 4000 or 6000 x-series oscilloscopes. figure 10 shows an example of the usb 2.0 real-time eye test. also included with this option is complete signal quality test report generation in html format. to see the complete list of supported tests, refer to the dsox4usbsq/ dsox6usbsq signal quality test option data sheet listed at the ended of this document. to perform physical layer conformance testing on the differential flexray bus, keysight provides a pc-based software package that you can download from keysights website at no additional charge. if the infiniivision x-series scope is licensed with the flexray, mask test, and segmented memory, you can perform automated physical layer tests at either receiver input or transmitter output test points. figure 10 shows an example of the generated report from a signal integrity voting test on a 10-mbs isolated 1 pulse. the test report includes comprehensive pass/ fail and margin analysis based on published specifications. refer to the tables in the specifications/characteristics section of this document on page 17 to see the entire list of 33 available flexray tests that can be selected and performed using the flexray physical layer conformance test software package. figure 9. arinc 429 100 kbps eye-diagram mask test. figure 10. usb 2.0 signal quality eye test based on usb-if physical layer compliance standards. figure 11. flexray signal integrity voting test performed on an isolated 1 bit. serial bus eye-diagram and pulse mask testing
07 | keysight | serial bus options for infiniivision x-series oscilloscopes - data sheet figure 12. keysights n2818a 200-mhz differential active probe. figure 14. keysights n2750a 1.5-ghz infiniimode differential active probe. figure 13. the n7013a extreme temperature probing kit for differential probes. probing differential serial buses many of todays serial buses are based on differential signaling including usb, can, can fd, flexray, mil-std 1553, and arinc 429. in addition, serial buses based on the rs232/uart protocol are often differential if implemented with rs422 or rs485 output drivers/ transceivers. keysight offers a wide range of differential active probes compatible with the infiniivision x-series oscilloscopes for various bandwidth and dynamic range applications. table 1 shows the differential probes that keysight recommends for each of the listed differential serial buses. if you need to connect to db9-subd connectors on your differential can, can fd and/or flexray bus, keysight also offers the can/flexray db9 probe head (part number 0960-2926) is shown in the inset picture of figure 12. when probing differential signals inside of environmental chambers at extreme temperatures, keysight offers the n7013a extreme temperature extension kit shown in figure 13. the n7013a is compatible with the n2791a and n2818a differential probes and can operate in temperatures ranging from -40 degrees to +85 degree celsius. to learn more about this probing solution, refer the extreme temperature probing solutions selection guide (publication number 5991-3504en) listed at the end of this document. the n2750a differential active probe shown in figure 14, which is recommended for hi-speed usb 2.0 measurement applications, is based on keysights infiniimode technology. with the press of a button, you can quickly toggle between viewing the differential signal, high-side signal, low-side signal, or the common mode signal on the usb 2.0 hi-speed bus without moving probe connections. table 1. recommended probes for differential buses differential bus (max bit rate) n2791a (25-mhz bandwidth) n2818a 1 (200-mhz bandwidth) n2750a (1.5-ghz bandwidth) can (1 mbps) x x can fd (10 mbps data phase) x flexray (10 mbps) x mil-std 1553 (1 mbps) x x arinc 429 (100 kbps) x x rs422/rs485 (10 mbps) x x hi-speed usb (480 mbps) x 1. the n2818a differential probe is not compatible with keysights infiniivision 2000 x-series oscilloscopes.
08 | keysight | serial bus options for infiniivision x-series oscilloscopes - data sheet specifcations/characteristics i 2 c specifcations/characteristics (dsox2embd, dsox3embd, and dsox4embd clock and data input source analog channels 1, 2, 3, or 4 digital channels d0 to d15 (3000, 4000 and 6000 x-series only) max clock/data rate up to 3.4 mbps triggering start condition stop condition missing acknowledge address with no acknowledge restart eeprom data read frame (start:addr7:read:ack:data) frame (start:addr7:write:ack:data) frame (start:addr7:read:ack:data:ack:data2) frame (start:addr7:write:ack:data:ack:data2) 10-bit write hardware-based decode data (hex digits in white) address decode size: 7 bits (excludes r/w bit) or 8 bits (includes r/w bit) read address (hex digits followed by r in yellow) write address (hex digits followed by w in light-blue) restart addresses (s in green, followed by hex digits, followed by r or w) acknowledges (suffxes a or ~a in the same color as the data or address preceding it) idle bus (mid-level bus trace in dark blue) active bus (bi-level bus trace in dark blue) unknown/error bus (bi-level bus trace in red) multi-bus analysis i 2 c plus one other serial bus, including another i 2 c bus. (3000, 4000 and 6000 x-series only)
09 | keysight | serial bus options for infiniivision x-series oscilloscopes - data sheet spi specifcations/characteristics (dsox2embd, dsox3embd, dsox4embd and dsox6embd) mosi, miso, clock, and cs input source analog channels 1, 2, 3, or 4 digital channels d0 to d15 (3000, 4000 and 6000 x-series only) max clock/data rate up to 25 mb/s triggering 4- to 64-bit data pattern during a user-specifed framing period framing period can be a positive or negative chip select (cs or ~cs) or clock idle time (timeout) hardware-based decode number of decode traces: 2 independent traces (miso and mosi) data (hex digits in white) unknown/error bus (bi-level bus trace in red) number of clocks/packet (xx clks in light-blue above data packet) idle bus (mid-level bus trace in dark blue) active bus (bi-level bus trace in dark blue) multi-bus analysis spi plus one other serial bus, excluding another spi bus. (3000, 4000 and 6000 x-series only) specifcations/characteristics (continued)
10 | keysight | serial bus options for infiniivision x-series oscilloscopes - data sheet rs232/uart specifcations/characteristics (dsox2comp, dsox3comp, dsox4comp and dsox6comp) tx and rx input source analog channels 1, 2, 3, or 4 digital channels d0 to d15 (3000, 4000 and 6000 x-series only) bus confguration C baud rates 100 b/s up to 8 mb/s C number of bits 5 to 9 C parity none, odd, or even C polarity idle low or idle high C bit order lsb out frst or msb out frst triggering rx start bit rx stop bit rx data rx 1:data (9-bit format) rx 0:data (9-bit format) rx x:data (9-bit format) rx or tx parity error tx start bit tx stop bit tx data tx 1:data (9-bit format) tx 0:data (9-bit format) tx x:data (9-bit format) burst (nth frame within burst defned by timeout) hardware-based decode C number of decode traces 2 independent traces (tx and rx) C data format binary, hex, or ascii-code characters C data byte display white characters if no parity error, red characters if parity or bus error C idle bus trace mid-level bus trace in blue C active bus trace bi-level trace in blue multi-bus analysis rs232/uart plus one other serial bus, including another rs232/uart bus. (3000, 4000 and 6000 x-series only) totalize/counter function total received frames total transmitted frames total parity error frames (with percentage) specifcations/characteristics (continued)
11 | keysight | serial bus options for infiniivision x-series oscilloscopes - data sheet usb 2.0 low- and full-speed specifcations/characteristics (dsox4usbfl and dsox6usbfl) usb input source (d+ & d-) analog channels 1, 2, 3, 4 digital channels d0-d15 speed low (1.5 mb/s) and full (12 mb/s) triggering start of packet (sop) end of packet (eop) suspend C when bus is idle for > 3 ms resume C when exiting an idle state > 10 ms reset C when se0 is > 10 ms token packet with specifed content data packet with specifed content handshake packet with specifed content special packet with specifed content all errors C any of the below error conditions pid error C if packet type feld does not match check feld crc5 error C if 5 bit crc error is detected crc16 error C if 16 bit crc error is detected glitch error C if two transitions occur in half a bit time bit stuff error C if >6 consecutive ones are detected se1 error C if se1 > 1 bit time hardware-based decode C base format hex, binary, ascii, or decimal data decode C token packets (excluding sof, 3 bytes) pid (yellow, out, in, setup, ping) pid check (yellow when valid, red when error detected) C numeric value address (blue, 7 bits) endpoint (green, 4 bits) crc (blue when valid, red when error detected, 5 bits) C token packets (sof, 3 bytes) pid (yellow, sof) pid check (yellow when valid, red when error detected, 5 bits) frame (green, 11-bits) C the frame number crc (blue when valid, red when error detected, 5 bits) C data packets (3 to 1027 bytes) pid (yellow, data0, data1, data2, mdata) pid check (yellow when valid, red when error detected, 16 bits) C handshake packets (1 byte) pid (yellow, ack, nak, stall, nyet, pre, err) pid check (yellow when valid, read when error detected) C numeric value hub addr (green, 7 bits) sc (blue, 1 bit) port (green, 7 bits) s & e|u (blue, 2 bits) et (green, 2 bits) crc (blue when valid, red when error detected, 5 bits C multi-bus analysis usb low-full-speed plus one other serial bus (including another usb bus) specifcations/characteristics (continued)
12 | keysight | serial bus options for infiniivision x-series oscilloscopes - data sheet specifcations/characteristics (continued) usb 2.0 high-speed specifcations/characteristics (dsox4usbh and dsox6usbh) usb differential input source analog channels 1, 2, 3, 4 (using a differential active probe) speed high (480 mb/s) triggering token packet with specifed content data packet with specifed content handshake packet with specifed content special packet with specifed content all errors C any of the below error conditions pid error C if packet type feld does not match check feld crc5 error C if 5 bit crc error is detected crc16 error C if 16 bit crc error is detected glitch error C if two transitions occur in half a bit time hardware-based decode base format hex, binary, ascii, or decimal data decode token packets (excluding sof, 3 bytes) pid (yellow, out, in, setup, ping) pid check (yellow when valid, red when error detected) C numeric value address (blue, 7 bits) endpoint (green, 4 bits) crc (blue when valid, red when error detected, 5 bits) token packets (sof, 3 bytes) pid (yellow, sof) pid check (yellow when valid, red when error detected, 5 bits) data packets (3 to 1027 bytes) frame (green, 11-bits) C the frame number crc (blue when valid, red when error detected, 5 bits) pid (yellow, data0, data1, data2, mdata) pid check (yellow when valid, red when error detected, 16 bits) handshake packets (1 byte) pid (yellow, ack, nak, stall, nyet, pre, err) pid check (yellow when valid, read when error detected) C numeric value hub addr (green, 7 bits) sc (blue, 1 bit) port (green, 7 bits) s & e|u (blue, 2 bits) et (green, 2 bits) crc (blue when valid, red when error detected, 5 bits multi-bus analysis n/a
13 | keysight | serial bus options for infiniivision x-series oscilloscopes - data sheet specifcations/characteristics (continued) can specifcations/characteristics (dsox2auto and dsox3auto) can input source analog channels 1, 2, 3, or 4 digital channels d0 to d15 non-differential. (3000 x-series only) signal types rx, tx, can_l, can_h, diff (l-h), diff (h-l) baud rates 10 kb/s up to 5 mb/s triggering start-of-frame (sof) remote frame id (rmt) data frame id (~rmt) remote or data frame id data frame id and data error frame all errors (includes protocol form errors that may not generate fagged error frames) acknowledge errors overload frames id length: 11 bits or 29 bits (extended) hardware-based decode frame id (hex digits in yellow) remote frame (rmt in green) data length code (dlc in blue) data bytes (hex digits in white) crc (hex digits in blue = valid, hex digits in red = error) error frame (bi-level bus trace and err message in red) form error (bi-level bus trace and ? in red) overload frame (ovrld in blue) idle bus (mid-level bus trace in dark blue) active bus (bi-level bus trace in dark blue) multi-bus analysis can plus one other serial bus, including another can bus. (3000 x-series only) totalize function total frames, total overload frames, total error frames, bus utilization (bus load) eye-diagram mask testing (3000 x-series only, requires dsox3mask) various downloadable mask fles available based on differential probing polarity, baud rate, and network length
14 | keysight | serial bus options for infiniivision x-series oscilloscopes - data sheet specifcations/characteristics (continued) can/can fd specifcations/characteristics (dsoxt3auto, dsox4auto, and dsox6auto) note: classic can 2.0 is a subset of can fd. can fd trigger and decode supports iso and non-iso can fd specifcations. both of these protocol standards are supported with the dsoxt3auto, dsox4auto, and dsox6auto option in an infniivision 3000t, 4000, and 6000 x-series oscilloscope. can input source analog channels 1, 2, 3, or 4 digital channels d0 to d15 non-differential signal types rx, tx, can_l, can_h, diff (l-h), diff (h-l) standard baud rates 10 kb/s up to 5 mb/s fd baud rates 10 kb/s up to 10 mb/s triggering sof (start-of-frame) eof (end-of-frame, fltered by id) data frame id (11 bits or 29 bits: extended) data frame id and data C non fd data frame id and data - fd remote frame id (rtr) remote or data frame id error frame (fltered by id) acknowledge error (fltered by id) form error (fltered by id) stuff error (fltered by id) crc error (fltered by id) spec error (includes ack, form, stuff, or crc error; flter by id) all errors (includes any spec error or error frame; fltered by id) brs bit (fltered by id of fd frames only) crc delimiter bit (fltered by id of fd frames only) esi bit active (fltered by id of fd frames only) esi bit passive (fltered by id of fd frame only) overload frames symbolic triggering (based on .dbc fle) message names message and signal values/encoded states (frst 8 bytes) hardware-based decode frame id (hex digits in yellow) remote frame (rmt in green) data length code (dlc = with decimal digits in blue) data bytes (hex digits in white) esi bit passive (frame type column in lister shaded yellow; fd frames only) error frame (bi-level red bus trace with err frame in red) stuff bit error (bi-level red bus trace with stuff err in red) form error (bi-level red bus trace with form err in red) acknowledge error (bi-level red bus trace with ack err in red) crc (hex digits in blue = valid, hex digits in red = error) overload frame (ovrld in blue) idle bus (mid-level dark blue bus trace) active bus (bi-level dark blue bus trace with embedded decode within) symbolic decode (based on .dbc fle) message names (alpha-numeric characters in yellow) signal names, value/encoded state (frst 8 bytes), and units (alpha-numeric characters in white) multi-bus analysis can/can fd plus one other serial bus, including another can/can fd bus totalize function (real time) total frames, total error frames with %, total spec errors, bus load in % can/can fd eye-diagram mask testing (requires dsox3mask/dsox4mask/ dsox6mask) various downloadable mask fles available based on differential probing polarity, baud rate, and network length
15 | keysight | serial bus options for infiniivision x-series oscilloscopes - data sheet lin specifcations/characteristics (dsox2auto, dsox3auto, dsoxt3auto, dsox4auto and dsox6auto) lin input source analog channels 1, 2, 3, or 4 digital channels d0 to d15 except 2000 x-series lin standards lin 1.3 or lin 2.x baud rates 2400 b/s to 625 kb/s triggering sync break frame id (0x00hex to 0x3fhex) frame id and data parity error checksum error symbolic decode (except 2000x)(based on .ldf fle) message names (alpha-numeric characters in yellow) signal names, value/encoded state and units (alpha-numeric characters in white) hardware-based decode frame id (6-bit hex digits in yellow) frame id and optional parity bits (8-bit hex digits in yellow if valid, red if parity bit error) data bytes (hex digits in white) check sum (hex digits in blue = valid, hex digits in red = error) sync error (sync in red) theader-max (thm in red) tframe-max (tfm in red) parity error (par in red) lin 1.3 wake-up error (wup in red) idle bus (mid-level bus trace in dark blue) active bus (bi-level bus trace in dark blue) symbolic triggering (except 2000x) (based on .dbc fle) message names message and signal values/encoded states multi-bus analysis lin plus one other serial bus, including another lin bus. (except 2000x) specifcations/characteristics (continued)
16 | keysight | serial bus options for infiniivision x-series oscilloscopes - data sheet specifcations/characteristics (continued) sent specifcations/characteristics (dsoxt3sensor, dsox4sensor, and dsox6sensor) can input source analog channels 1, 2, 3, or 4 digital channels d0 to d15 non-differential clock period 1 s to 300 s with user-defned tolerance setting from 3 to 30% number of nibbles 1 to 6 idle state high or low crc format 2008 or 2010 standards pause pulse on/off message format fast nibbles (all) fast signals (only) fast + short serial fast + enhanced serial (automatically detects bit format: 12-bit data/8-bit id or 16-bit data/4-bit id) short serial (only) enhanced serial (only) number of defned signals 1 to 6 (each specifed by start bit #, number of bits, and nibble order) numerical format of signals hexadecimal, unsigned decimal, or transfer function with user-defned multiplier and offset for each defned signal triggering start of fast channel message start of slow channel message fast channel status & communication nibble + data slow channel message id slow channel message id + data tolerance violation (sync pulse width exceeds user-specifed tolerance) fast channel crc error slow channel crc error all crc errors pulse period error (if nibbles are < 12 or > 27 ticks wide) successive sync pulses error (if consecutive sync pulse widths are greater than 1/64 difference) fast channel decode status & communication nibble (binary digits in green) data (hex, unsigned decimal, or transfer function digits in white based on user-defned signal format) crc error (hex digit in blue = valid, hex digit in red = error) pulse period error (< or > in red) slow channel decode message id (hex digits in yellow) data (hex digits in white) crc (hex digits in blue = valid, hex digits in red = error) multi-bus analysis sent plus one other serial bus, including another sent bus
17 | keysight | serial bus options for infiniivision x-series oscilloscopes - data sheet specifcations/characteristics (continued) cxpi specifcations/characteristics (dsoxt3cxpi and DSOX4CXPI) cxpi input source analog channels 1, 2, 3 or 4 baud rates 9.6 kb/s to 40 kb/s (20 kb/s typical) with tolerance setting triggering sof (start-of-frame) eof (end-of-frame) ptype frame id (ptpye present or not present) frame id + info + data frame id + info + data (long frame) crc feld error (fltered by id) parity error inter-byte space error (fltered by id) inter-frame space error (fltered by id) framing error (fltered by id) data length error (fltered by id) sample error all errors sleep frame wakeup pulse hardware-based decode frame id (hex digits in yellow if valid or red if parity error) data length code (dlc = with decimal digits in blue) network management (nm) bits (binary digits in green) counter (ct) bits (binary digits in yellow) data (hex digits in white) crc (hex digits in blue = valid, hex digits in red = error) idle bus (mid-level dark blue bus trace) active bus (bi-level dark blue bus trace with embedded decode within) inter-byte space error (ibs err in red) data length error (len err in red) sleep mode (sleep mode in orange within bi-level orange bus trace) wakeup pulse (wakeup pulse in blue with bi-level blue bus trace) multi-bus analysis cxpi plus one other serial bus
18 | keysight | serial bus options for infiniivision x-series oscilloscopes - data sheet specifcations/characteristics (continued) flexray specifcations/characteristics (dsox3flex, dsox4flex and dsox6flex) flexray input source channel 1, 2, 3, or 4 (using differential probe) flexray channels a or b baud rates 2.5 mbps, 5.0 mbps, and 10 mbps frame triggering frame type: startup (sup), not startup (~sup), sync (sync), not sync (~sync), null (null), not null (~null), normal (norm), and all frame id: 1 to 2047 (decimal format), and all cycle - base: 0 to 63 (decimal format), and all repetition: 1, 2, 4, 8, 16, 32, 64 (decimal format), and all error triggering all errors header crc error frame crc error event triggering wake-up tss (transmission start sequence) bss (byte start sequence) fes/dts (frame end or dynamic trailing sequence) frame decoding frame type (norm, sync, sup, null in blue) frame id (decimal digits in yellow) payload-length (decimal number of words in green) header crc (hex digits in blue if valid, or red digits if invalid) cycle number (decimal digits in yellow) data bytes (hex digits in white) frame crc (hex digits in blue if valid, or red digits totalize function total frames total synchronization frames total null frames eye-diagram mask testing (requires dsox3mask mask test option plus downloadable mask fles) tp1 standard voltage (10 mbps only) tp1 increased voltage (10 mbps only) tp11 standard voltage (10 mbps only) tp11 increased voltage (10 mbps only) tp4 10 mbps, tp4 5 mbps and tp4 2.5 mbps multi-bus analysis flexray plus one other serial bus (including another flexray bus)
19 | keysight | serial bus options for infiniivision x-series oscilloscopes - data sheet flexray physical layer conformance test software requires flexray option (dsox3flex/dsox4flex/dsox6flex) mask test option (dsox3mask/dsox4mask/dsox6mask) segmented memory option (dsox3sgm or standard on 3000t, 4000 and 6000 x-series) table 1. receiver input tests parameter tested test description eye-diagram mask tests: C tp4 C all receiver mask test on all frames C tp4 C id receiver mask test on specifed frame signal integrity voting tests on 13 mhz low-pass fltered isolated 1: C udata1top required maximal level C dbitshort shortest single bit C dbitlengthvariation bit asymmetry C dedge01 rising edge duration (-300 mv to +300 mv) C dedge10 falling edge duration (+300 mv to -300 mv) C dedgemax slowest edge C sq1 isolated 1 voted signal quality signal integrity voting tests on 13 mhz low-pass fltered isolated 0: C udata0top required minimal level C dbitshort shortest single bit C dbitlengthvariation bit asymmetry C dedge01 rising edge duration (-300 mv to +300 mv) C dedge10 falling edge duration (+300 mv to -300 mv) C dedgemax slowest edge C sq0 isolated 0 voted signal quality advanced diagnostic tests: C gdtsstransmitter transmitted tss width @ receiver C mct mean corrected cycle time C ubusrx-data data 1 amplitude C -ubusrx-data data 0 amplitude C urx-idle mean idle level C dbusrx01 rise time data0 to data1 (C300 mv to +300 mv) C dbusrx10 fall time data1 to data0 (+300 mv to -300 mv) table 2. transmitter output tests parameter tested test description eye-diagram mask tests (10 mbs only): C tp1 C std v mask test on standard voltage bus driver output C tp1 C incr v mask test on increased voltage bus driver output C tp11 C std v mask test on standard voltage active star output C p11 C incr v mask test on increased voltage active star output advanced diagnostic tests: C gdtsstransmitter transmitted tss width C ubustx-data data 1 amplitude C -ubustx-data data 0 amplitude C urx-idle mean idle level C dbustx01 rise time data0 to data1 (20 to 80%) C dbustx10 fall time data1 to data0 (80 to 20%)
20 | keysight | serial bus options for infiniivision x-series oscilloscopes - data sheet i 2 s specifcations/characteristics (dsox3audio, dsox4audio, and dsox6audio) sclk, ws, and sdata input source analog channels 1, 2, 3, or 4 digital channels d0 to d15 bus configuration: C transmitted word size 4 to 32 bits (user selectable) C decoded/receiver word size 4 to 32 bits (user selectable) C alignment standard, left-justified, or right-justified C word select - low left-channel or right-channel C sclk slope rising edge or falling edge C decoded base hex (2s complement) or signed decimal baud rates 2400 b/s to 625 kb/s triggering: C audio channel audio left, audio right, or either C trigger modes = (equal to entered data value) (not equal to entered data value) < (less than entered data value) > (greater than entered data value) >< (within range of entered data values) <> (out of range of entered data values) increasing value that crosses armed (<=) and trigger (>=) entered data values decreasing value that crosses armed (>=) and trigger (<=) entered data values hardware-based decode: C left channel l: decoded value in white C right channel r: decoded value in green C error err in red (mismatch between transmitted and received word size, or invalid input signaling) C word size indicator # of tx / # of rx clks in blue displayed above each decoded work multi-bus analysis i 2 s plus one other serial bus ( excluding another i 2 s bus) specifcations/characteristics (continued)
21 | keysight | serial bus options for infiniivision x-series oscilloscopes - data sheet specifcations/characteristics (continued) mil-std 1553 specifcations/characteristics (dsox3aero, dsox4aero, and dsox6aero) mil-std 1553 input source analog channels 1, 2, 3, or 4 (using a differential active probe) triggering data word start data word stop command/status word start command/status word stop remote terminal address (hex) remote terminal address (hex) + 11 bits (binary) parity error sync error manchester error color-coded, hardware-accelerated decode base: hex or binary command or status word (c/s in green) remote terminal address (hex or binary digits in green) 11 bits following rta (hex or binary digits in green) data word (d in white) data word bits (hex or binary digits in white) parity error (all decoded text in red) synchronization error (sync in red) manchester error (manch in red) eye-diagram mask testing (requires dsox3mask mask test option plus downloadable mask fles) system xfmr-coupled input system direct-coupled input bc xfmr-coupled input bc direct-coupled input rt xfmr-coupled input rt xfmr-coupled input multi-bus analysis mil-std 1553 plus one other serial bus, (including another mil-std 1553 bus)
22 | keysight | serial bus options for infiniivision x-series oscilloscopes - data sheet specifcations/characteristics (continued) arinc 429 specifcations/characteristics (dsox3aero, dsox4aero and dsox6aero) arinc 429 input source analog channels 1, 2, 3, or 4 (using a differential active probe) high (100 kbps) baud rates low (12.5 kbps) triggering word start word stop label (octal) label (octal) + bits (binary) label range (octal) parity error word error gap error word or gap error all errors all bits (useful for eye-diagram testing) all 0 bits all 1 bits color-coded, hardware-accelerated decode word format: label/sdi/data/ssm or label/data/ssm or label/data label (octal digits in yellow) sdi (binary digits in blue) data (hex or binary digits in white) ssm (binary digits in green) errors (text in red) totalize function total words total errors eye-diagram and pulse mask testing (requires dsox3mask plus downloadable mask fles) 100 kbps eye test 100 kbps 1s test 100 kbps 0s test 100 kbps null test 12.5 kbps eye test 12.5 kbps 1s test 12.5 kbps 0s test 12.5 kbps null test multi-bus analysis arinc 429 plus one other bus (including another arinc 429 bus)
23 | keysight | serial bus options for infiniivision x-series oscilloscopes - data sheet ordering information the various serial bus options are compatible on most models of the keysight infiniivision 3000, 4000 and 6000 x-series oscilloscopes. the entry-level 2000 x-series oscilloscopes support only the i 2 c/spi, rs232/uart, and can/lin options. existing infiniivision x-series oscilloscopes can also be upgraded with these options. for most model numbers, the number after dsox tells you to which series of oscilloscope it applies. for example, dsox2embd applies to the 2000 x-series and dsox3embd applies to the 3000 x-series. t in the model number indicates that this option is available in the 3000t x-series, but not in the 3000a x-series. model number description dsox2embd, dsox3embd, dsox4embd or dsox6embd i 2 c and spi trigger and decode dsox2comp, dsox3comp, dsox4comp or dsox6comp rs232/uart trigger and decode dsox2auto or dsox3auto can and lin trigger and decode dsoxt3auto, dsox4auto, or dsox6auto can, can fd, and lin trigger and decode, including can-dbc and lin-ldf symbolic decoding dsoxt3sensor, dsox4sensor, or dsox6sensor single edge nibble transmission (sent) trigger and decode dsox3tcxpi or DSOX4CXPI clock extension peripheral interface (cxpi) trigger and decode dsox3flex, dsox4flex or dsox6flex flexray trigger and decode dsox3aero, dsox4aero or dsox6aero mil-std 1553 and arinc 429 trigger and decode dsox3audio, dsox4audio or dsox6audio i 2 s trigger and decode dsox4usbfl or dsox6usbfl usb 2.0 low- and full-speed trigger and decode dsox4usbh or dsox6usbh usb 2.0 hi-speed trigger and decode (1 ghz and 1.5 ghz bandwidth models of 4000 x-series only) dsox4usbsq or dsox6usbsq usb 2.0 signal quality test (hi-speed tests require 1.5 ghz bandwidth models) dsox2sgm and dsox3sgm segmented memory (standard on 3000t, 4000 and 6000 x-series models) dsox2mask, dsox3mask, dsox4mask or dsox6mask mask test option n2791a 25-mhz differential active probe n2818a 200-mhz differential active probe n7013a extreme temperature probing kit for differential active probes n2750a 1.5 ghz differential active probe (recommended for usb 2.0 hi-speed applications) 0960-2926 db9 probe head adapter for n2791a and n2818a additional options and accessories are available for keysights infiniivision oscilloscopes. refer to the first four documents in the list below for ordering information about these additional options and accessories.
24 | keysight | serial bus options for infiniivision x-series oscilloscopes - data sheet related keysight literature publication title publication number infniivision 2000 x-series oscilloscopes - data sheet 5990-6618en infniivision 3000t x-series oscilloscopes - data sheet 5992-0140en infniivision 4000 x-series oscilloscopes - data sheet 5991-1103en infniivision 6000 x-series oscilloscopes - data sheet 5991-4087en infniivision oscilloscope probes and accessories - selection guide 5968-8153en extreme temperature probing solutions for oscilloscope measurements - data sheet 5990-3504en n2792a/n2818a 200 mhz and n2793a/n2819a 800 mhz differential probes - data sheet 5990-4753en n2750a/51a/52a infniimode differential active probes - data sheet 5991-0560en dsox4usbsq and dsox6usbsq usb 2.0 signal quality test option for 4000 and 6000 x-series - data sheet 5991-1762en using oscilloscope segmented memory for serial bus applications - application note 5990-5817en characterizing hi-speed usb 2.0 serial buses in embedded designs - data sheet 5991-1148en debug automotive designs faster with can-dbc symbolic trigger and decode - application note 5991-2847en can eye-diagram mask testing - application note 5991-0484en can fd eye-diagram mask testing - application note 5992-0437en characterizing can bus arbitration using infniivision 4000/6000 x-series oscilloscope - application note 5991-4166en flexray physical layer eye-diagram mask testing - application note 5990-4923en mil-std 1553 eye-diagram mask testing C application note 5990-9324en arinc 429 eye-diagram and pulse-shape mask testing C application note 5990-9325en to download these documents, insert the publication number in the url: http://cp.literature.keysight.com/litweb/pdf/xxxx-xxxxen.pdf keysight oscilloscopes multiple form factors from 20 mhz to > 90 ghz | industry leading specs | powerful applications product web site for the most up-to-date and complete application and product information, please visit our product web sites at: C www.keysight.com/find/2000x-series C www.keysight.com/find/3000tx-series C www.keysight.com/find/4000x-series C www.keysight.com/find/6000x-series
25 | keysight | serial bus options for infiniivision x-series oscilloscopes - data sheet www.axiestandard.org advancedtca ? extensions for instrumentation and test (axie) is an open standard that extends the advancedtca for general purpose and semiconductor test. the business that became keysight was a founding member of the axie consortium. atca ? , advancedtca ? , and the atca logo are registered us trademarks of the pci industrial computer manufacturers group. www.lxistandard.org lan extensions for instruments puts the power of ethernet and the web inside your test systems. the business that became keysight was a founding member of the lxi consortium. www.pxisa.org pci extensions for instrumentation (pxi) modular instrumentation delivers a rugged, pc-based high-performance measurement and automation system.
26 | keysight | serial bus options for infiniivision x-series oscilloscopes - data sheet this information is subject to change without notice. ? keysight technologies, 2012 - 2016 published in usa, june 9, 2016 5990-6677en www.keysight.com for more information on keysight technologies products, applications or services, please contact your local keysight office. the complete list is available at: www.keysight.com/find/contactus americas canada (877) 894 4414 brazil 55 11 3351 7010 mexico 001 800 254 2440 united states (800) 829 4444 asia pacifc australia 1 800 629 485 china 800 810 0189 hong kong 800 938 693 india 1 800 11 2626 japan 0120 (421) 345 korea 080 769 0800 malaysia 1 800 888 848 singapore 1 800 375 8100 taiwan 0800 047 866 other ap countries (65) 6375 8100 europe & middle east austria 0800 001122 belgium 0800 58580 finland 0800 523252 france 0805 980333 germany 0800 6270999 ireland 1800 832700 israel 1 809 343051 italy 800 599100 luxembourg +32 800 58580 netherlands 0800 0233200 russia 8800 5009286 spain 800 000154 sweden 0200 882255 switzerland 0800 805353 opt. 1 (de) opt. 2 (fr) opt. 3 (it) united kingdom 0800 0260637 for other unlisted countries: www.keysight.com/find/contactus (bp-06-08-16) dekra certified iso9001 quality management system www.keysight.com/go/quality keysight technologies, inc. dekra certified iso 9001:2015 quality management system mykeysight www.keysight.com/find/mykeysight a personalized view into the information most relevant to you. keysight infoline www.keysight.com/find/infoline keysights insight to best in class information management. free access to your keysight equipment company reports and e-library. keysight services keysight services www.keysight.com/find/service our deep offering in design, test, and measurement services deploys an industry-leading array of people, processes, and tools. the result? we help you implement new technologies and engineer improved processes that lower costs. three-year warranty www.keysight.com/find/threeyearwarranty keysights committed to superior product quality and lower total cost of ownership. keysight is the only test and measurement company with three-year warranty standard on all instruments, worldwide. and, we provide a one-year warranty on many accessories, calibration devices, systems and custom products. keysight assurance plans www.keysight.com/find/assuranceplans up to ten years of protection and no budgetary surprises to ensure your instruments are operating to specification, so you can rely on accurate measurements. keysight channel partners www.keysight.com/find/channelpartners get the best of both worlds: keysights measurement expertise and product breadth, combined with channel partner convenience. www.keysight.com/find/2000x-series www.keysight.com/find/3000x-series www.keysight.com/find/4000x-series www.keysight.com/find/6000x-series evolving our unique combination of hardware, software, support, and people can help you reach your next breakthrough. we are unlocking the future of technology. from hewlett-packard to agilent to keysight


▲Up To Search▲   

 
Price & Availability of DSOX4CXPI

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X